Pierce™ Dextran Desalting Columns (5K MWCO)
Pierce™ Dextran Desalting Columns (5K MWCO)
Thermo Scientific™

Pierce™ Dextran Desalting Columns (5K MWCO)

Ready-to-use, gel-filtration Thermo Scientific Pierce Dextran Desalting Columns can separate proteins and macromolecules from low-molecular weight buffer salts and reagents up to 5000 Daltons (5 kDa) in 5- or 10-mL volumes.
Have Questions?
更改视图buttonViewtableView
货号VolumeMetric
43230
43233
货号 43230
价格(CNY)/ 5 columns
2,486.00
-
添加至购物车
请求批量或定制报价
价格(CNY)/ 5 columns
2,486.00
添加至购物车
Pierce™ Dextran Desalting Columns (5K MWCO)
货号43230
价格(CNY)/ 5 columns
2,486.00
-
添加至购物车
Thermo Scientific Pierce Dextran Desalting Columns are ready-to-use, disposable, gel-filtration columns for separating proteins and other macromolecules from low molecular-weight buffer salts and reagents.

Applications
• Removing salts from protein solutions
• Eliminating phenol from nucleic acid preparations
• Separating excess crosslinker from conjugate preparations
• Removing excess derivatizing agents from modified proteins
• Withdrawing unreacted dye from fluorescent antibodies
• Eliminating free radiolabel from labeled proteins
• Buffer exchange

Gravity-flow gel filtration using dextran desalting columns
Gravity-flow gel filtration involves the chromatographic separation of molecules of different dimensions based on their relative abilities to penetrate a suitable stationary phase. A chromatographic matrix, usually consisting of very small, uncharged porous particles in an aqueous solution, is packed into a column and then used for separation via size exclusion. Different levels of separation can be achieved based on the pore size of the medium packed into the desalting column—in our case, dextran. With size exclusion filtration, large molecules are excluded from the internal pores of the gel and emerge from the column first. Smaller molecules can penetrate the pores, then progress through the column at a slower rate. These smaller molecules are subsequently flushed through the column with additional buffer volume. Our Dextran Desalting Columns are rigid for easy handling and provide excellent flow properties. Dextran is stable in water, salt solutions, organic solvents and alkaline or weakly acidic solutions. Dextran is also heat-stable and can be autoclaved dry or in solution at a neutral pH for 30 minutes at 120°C without affecting its chromatographic properties.

仅供科研使用。不可用于诊断程序。
规格
描述葡聚糖脱盐柱 (5K MWCO, 5mL)
产品类型脱盐柱
产品规格重力流柱
纯化目标缓冲液置换,蛋白质
色谱柱类型尺寸排阻,葡聚糖树脂
截留分子量 (MWCO)5.0 kDa
产品线Pierce™
一次性
数量5柱
Unit Size5 columns
内容与储存
在室温下或 4°C 下储存。